Het voorbeeldpakket bevat 39 bewust geplante afwijkingen (waarden, materialen, tags, ontbrekende paragrafen, verouderde verwijzingen, stempels en maten op tekeningen, Nederlandstalige procedure). Hier wordt de laatst voltooide run op het voorbeeldpakket gescoord.
run 9d8ce9bbb27f · 20 Oct 2026 11:29 UTC · LongCat 2.5 (free fallback model)
| gepland | gevonden | recall | bevindingen | precisie | |
|---|---|---|---|---|---|
| High | 19 | 19 | 100% | 20 | 100% |
| Low | 6 | 6 | 100% | 6 | 83% |
| Medium | 11 | 11 | 100% | 14 | 85% |
| gepland | gevonden | recall | bevindingen | precisie | |
|---|---|---|---|---|---|
| DOCX | 10 | 10 | 100% | 12 | 83% |
| DWG | 3 | 3 | 100% | 3 | 100% |
| DXF | 6 | 6 | 100% | 6 | 100% |
| 7 | 7 | 100% | 9 | 88% | |
| XLSX | 10 | 10 | 100% | 10 | 100% |
| gepland | gevonden | recall | bevindingen | precisie | |
|---|---|---|---|---|---|
| EN | 32 | 32 | 100% | 34 | 97% |
| NL | 4 | 4 | 100% | 6 | 66% |
run c9e39d901d9e
| ID | Document | Afwijking | Resultaat |
|---|---|---|---|
| D01 | NCT-INS-DS-0101 | Calibrated range 0-100 barg is below 1.1 x design pressure (165 barg). | ✓ rule |
| D02 | NCT-INS-DS-0101 | Ingress protection IP65 instead of IP66. | ✓ rule |
| D03 | NCT-INS-DS-0101 | Tag 'PT-1012' does not follow the tag format. | ✓ rule |
| D04 | NCT-INS-DS-0101 | SIS transmitter 110-PT-1013 is only SIL 1 capable. | ✓ rule |
| D06 | NCT-MEC-SP-0201 | Body material ASTM A105 for valves exposed to -46 degC. | ✓ rule |
| D07 | NCT-MEC-SP-0201 | O-ring seals in standard NBR, not RGD-qualified. | ✓ agent |
| D08 | NCT-MEC-SP-0201 | No fire-safe section. | ✓ rule |
| D09 | NCT-MEC-SP-0201 | Fugitive emission class C instead of class B. | ✓ rule |
| D10 | NCT-MEC-SP-0201 | Refers to superseded Design Basis NCT-PRC-DB-0001 Rev C. | ✓ rule |
| D11 | NCT-MEC-SP-0201 | Maximum allowable working pressure given as 2,100 psi (imperial unit). | ✓ rule |
| D12 | NCT-PRC-PID-0301 | Title block field APPROVED is empty. | ✓ rule |
| D13 | NCT-PRC-PID-0301 | Instrument 110-PT-1014 on the P&ID is not in the instrument index. | ✓ rule |
| D14 | NCT-PRC-PID-0301 | Line 16"-CO2-1003-B9C is not in the line list. | ✓ rule |
| D15 | NCT-PRC-PID-0301 | Note states design pressure 135 barg; design basis is 150 barg. | ✓ rule |
| D17 | NCT-PRC-PID-0302 | Landfall ESD valve 120-XV-2001 shown as Class 600. | ✓ rule |
| D18 | NCT-PRC-PID-0302 | Title block revision 'C1' is not a valid revision code. | ✓ rule |
| D19 | NCT-PRC-PID-0302 | Instrument 120-TT-2012 on the P&ID is not in the instrument index. | ✓ rule |
| D20 | NCT-PIP-LL-0401 | Line 32"-CO2-2001-B9C design pressure 140 barg instead of 150 barg. | ✓ rule |
| D21 | NCT-PIP-LL-0401 | Line 16"-CO2-1002-B9C corrosion allowance 1.5 mm instead of 3.0 mm. | ✓ rule |
| D22 | NCT-PIP-LL-0401 | Vent line 2"-VNT-1005-L9C minimum design temperature -20 degC instead of -46 degC. | ✓ rule |
| D23 | NCT-INS-IL-0501 | Tag 110-PT-1011 appears twice. | ✓ rule |
| D24 | NCT-INS-IL-0501 | Instrument references P&ID NCT-PRC-PID-0399, which does not exist. | ✓ rule |
| D25 | NCT-INS-IL-0501 | Index range for 110-PT-1013 is 0-100 barg. | ✓ rule |
| D26 | NCT-PIP-CA-0601 | Calculation uses design pressure 135 barg. | ✓ rule |
| D27 | NCT-PIP-CA-0601 | Corrosion allowance 1.0 mm. | ✓ rule |
| D28 | NCT-PIP-CA-0601 | Line pipe grade L485ME is not an allowed grade. | ✓ rule |
| D29 | NCT-PIP-CA-0601 | Design factor 0.77 exceeds 0.72. | ✓ rule |
| D30 | NCT-MEC-PR-0701 | Houdtijd 8 uur (24 h required). | ✓ rule |
| D31 | NCT-MEC-PR-0701 | No drying section / dew point requirement. | ✓ rule |
| D32 | NCT-MEC-PR-0701 | Testdruk 210 barg (225 barg required). | ✓ rule |
| D33 | NCT-MEC-PR-0701 | Recorder calibration up to 12 months old allowed (6 months required). | ✓ rule |
| D35 | NCT-CIV-DW-0801 | Vent stack 45 m from the site boundary (60 m required). | ✓ rule |
| D36 | NCT-CIV-DW-0801 | Control room 22 m from the compressor building (30 m required). | ✓ rule |
| D37 | NCT-QAC-ITP-0901 | Girth weld NDT extent 10% instead of 100%. | ✓ rule |
| D38 | NCT-QAC-ITP-0901 | References procedure NCT-QAC-PR-0999, which is not in the document register. | ✓ rule |
| D39 | NCT-QAC-ITP-0901 | Pressure test is a hold point for the contractor only; the owner only reviews records (owner hold point required). | ✓ agent |