Review quality

Precision and recall against the planted non-conformities

The sample package contains 39 deliberately planted non-conformities (values, materials, tags, missing sections, outdated references, drawing title blocks and dimensions, Dutch-language procedure). The latest completed run on the sample package is scored here.

Revision A

run 9d8ce9bbb27f · 20 Oct 2026 11:29 UTC · LongCat 2.5 (free fallback model)

100%
recall · 36 of 36 planted found
92%
precision · 37 of 40 findings hit a planted defect
34 / 2
found by rules / by agents
3
findings not in the planted set (listed below)

By priority

plantedfoundrecallfindingsprecision
High1919100%20100%
Low66100%683%
Medium1111100%1485%

By file format

plantedfoundrecallfindingsprecision
DOCX1010100%1283%
DWG33100%3100%
DXF66100%6100%
PDF77100%988%
XLSX1010100%10100%

By document language

plantedfoundrecallfindingsprecision
EN3232100%3497%
NL44100%666%

Revision B: revision tracking

run c9e39d901d9e

6/6
fixed defects marked resolved
3/3
defects introduced in revision B found as new
100%
recall on the revised package (33/33)
97%
precision on the revised package

Planted non-conformities (revision A)

IDDocumentDefectResult
D01NCT-INS-DS-0101Calibrated range 0-100 barg is below 1.1 x design pressure (165 barg).✓ rule
D02NCT-INS-DS-0101Ingress protection IP65 instead of IP66.✓ rule
D03NCT-INS-DS-0101Tag 'PT-1012' does not follow the tag format.✓ rule
D04NCT-INS-DS-0101SIS transmitter 110-PT-1013 is only SIL 1 capable.✓ rule
D06NCT-MEC-SP-0201Body material ASTM A105 for valves exposed to -46 degC.✓ rule
D07NCT-MEC-SP-0201O-ring seals in standard NBR, not RGD-qualified.✓ agent
D08NCT-MEC-SP-0201No fire-safe section.✓ rule
D09NCT-MEC-SP-0201Fugitive emission class C instead of class B.✓ rule
D10NCT-MEC-SP-0201Refers to superseded Design Basis NCT-PRC-DB-0001 Rev C.✓ rule
D11NCT-MEC-SP-0201Maximum allowable working pressure given as 2,100 psi (imperial unit).✓ rule
D12NCT-PRC-PID-0301Title block field APPROVED is empty.✓ rule
D13NCT-PRC-PID-0301Instrument 110-PT-1014 on the P&ID is not in the instrument index.✓ rule
D14NCT-PRC-PID-0301Line 16"-CO2-1003-B9C is not in the line list.✓ rule
D15NCT-PRC-PID-0301Note states design pressure 135 barg; design basis is 150 barg.✓ rule
D17NCT-PRC-PID-0302Landfall ESD valve 120-XV-2001 shown as Class 600.✓ rule
D18NCT-PRC-PID-0302Title block revision 'C1' is not a valid revision code.✓ rule
D19NCT-PRC-PID-0302Instrument 120-TT-2012 on the P&ID is not in the instrument index.✓ rule
D20NCT-PIP-LL-0401Line 32"-CO2-2001-B9C design pressure 140 barg instead of 150 barg.✓ rule
D21NCT-PIP-LL-0401Line 16"-CO2-1002-B9C corrosion allowance 1.5 mm instead of 3.0 mm.✓ rule
D22NCT-PIP-LL-0401Vent line 2"-VNT-1005-L9C minimum design temperature -20 degC instead of -46 degC.✓ rule
D23NCT-INS-IL-0501Tag 110-PT-1011 appears twice.✓ rule
D24NCT-INS-IL-0501Instrument references P&ID NCT-PRC-PID-0399, which does not exist.✓ rule
D25NCT-INS-IL-0501Index range for 110-PT-1013 is 0-100 barg.✓ rule
D26NCT-PIP-CA-0601Calculation uses design pressure 135 barg.✓ rule
D27NCT-PIP-CA-0601Corrosion allowance 1.0 mm.✓ rule
D28NCT-PIP-CA-0601Line pipe grade L485ME is not an allowed grade.✓ rule
D29NCT-PIP-CA-0601Design factor 0.77 exceeds 0.72.✓ rule
D30NCT-MEC-PR-0701Houdtijd 8 uur (24 h required).✓ rule
D31NCT-MEC-PR-0701No drying section / dew point requirement.✓ rule
D32NCT-MEC-PR-0701Testdruk 210 barg (225 barg required).✓ rule
D33NCT-MEC-PR-0701Recorder calibration up to 12 months old allowed (6 months required).✓ rule
D35NCT-CIV-DW-0801Vent stack 45 m from the site boundary (60 m required).✓ rule
D36NCT-CIV-DW-0801Control room 22 m from the compressor building (30 m required).✓ rule
D37NCT-QAC-ITP-0901Girth weld NDT extent 10% instead of 100%.✓ rule
D38NCT-QAC-ITP-0901References procedure NCT-QAC-PR-0999, which is not in the document register.✓ rule
D39NCT-QAC-ITP-0901Pressure test is a hold point for the contractor only; the owner only reviews records (owner hold point required).✓ agent

Findings outside the planted set

Counted as false positives for precision. Some may be genuine issues the corpus author did not plant; they are shown so you can judge.

agent
NCT-MEC-PR-0701 · NCT-R-AFP-005
The instrumentation section lists pressure and temperature recording equipment but does not mention a calibrated hygrometer or dew point measurement at the far end of the section.
agent
NCT-MEC-PR-0701 · NCT-R-AFP-016
The requirement allows dry air or nitrogen as drive medium; the procedure restricts the medium to dry air only, which is more restrictive than the specification and omits the nitrogen option.
agent
NCT-PIP-CA-0601 · NCT-R-PIP-006
The SMYS input is traced only to 'ISO 3183 (number only)', which is not a referenced project document with a revision, so the input is not traceable as required.
How to read this: the requirements register, the documents and the planted defects were all written by PitchAI for this demo, and the deterministic rules were configured from the register. The scores show that the pipeline works end to end on known defects; they are not a claim about quality on real project documents. In a pilot, the same measurement runs on documents engineers have already reviewed, with their comments as the reference.