The sample package contains 39 deliberately planted non-conformities (values, materials, tags, missing sections, outdated references, drawing title blocks and dimensions, Dutch-language procedure). The latest completed run on the sample package is scored here.
run 9d8ce9bbb27f · 20 Oct 2026 11:29 UTC · LongCat 2.5 (free fallback model)
| planted | found | recall | findings | precision | |
|---|---|---|---|---|---|
| High | 19 | 19 | 100% | 20 | 100% |
| Low | 6 | 6 | 100% | 6 | 83% |
| Medium | 11 | 11 | 100% | 14 | 85% |
| planted | found | recall | findings | precision | |
|---|---|---|---|---|---|
| DOCX | 10 | 10 | 100% | 12 | 83% |
| DWG | 3 | 3 | 100% | 3 | 100% |
| DXF | 6 | 6 | 100% | 6 | 100% |
| 7 | 7 | 100% | 9 | 88% | |
| XLSX | 10 | 10 | 100% | 10 | 100% |
| planted | found | recall | findings | precision | |
|---|---|---|---|---|---|
| EN | 32 | 32 | 100% | 34 | 97% |
| NL | 4 | 4 | 100% | 6 | 66% |
run c9e39d901d9e
| ID | Document | Defect | Result |
|---|---|---|---|
| D01 | NCT-INS-DS-0101 | Calibrated range 0-100 barg is below 1.1 x design pressure (165 barg). | ✓ rule |
| D02 | NCT-INS-DS-0101 | Ingress protection IP65 instead of IP66. | ✓ rule |
| D03 | NCT-INS-DS-0101 | Tag 'PT-1012' does not follow the tag format. | ✓ rule |
| D04 | NCT-INS-DS-0101 | SIS transmitter 110-PT-1013 is only SIL 1 capable. | ✓ rule |
| D06 | NCT-MEC-SP-0201 | Body material ASTM A105 for valves exposed to -46 degC. | ✓ rule |
| D07 | NCT-MEC-SP-0201 | O-ring seals in standard NBR, not RGD-qualified. | ✓ agent |
| D08 | NCT-MEC-SP-0201 | No fire-safe section. | ✓ rule |
| D09 | NCT-MEC-SP-0201 | Fugitive emission class C instead of class B. | ✓ rule |
| D10 | NCT-MEC-SP-0201 | Refers to superseded Design Basis NCT-PRC-DB-0001 Rev C. | ✓ rule |
| D11 | NCT-MEC-SP-0201 | Maximum allowable working pressure given as 2,100 psi (imperial unit). | ✓ rule |
| D12 | NCT-PRC-PID-0301 | Title block field APPROVED is empty. | ✓ rule |
| D13 | NCT-PRC-PID-0301 | Instrument 110-PT-1014 on the P&ID is not in the instrument index. | ✓ rule |
| D14 | NCT-PRC-PID-0301 | Line 16"-CO2-1003-B9C is not in the line list. | ✓ rule |
| D15 | NCT-PRC-PID-0301 | Note states design pressure 135 barg; design basis is 150 barg. | ✓ rule |
| D17 | NCT-PRC-PID-0302 | Landfall ESD valve 120-XV-2001 shown as Class 600. | ✓ rule |
| D18 | NCT-PRC-PID-0302 | Title block revision 'C1' is not a valid revision code. | ✓ rule |
| D19 | NCT-PRC-PID-0302 | Instrument 120-TT-2012 on the P&ID is not in the instrument index. | ✓ rule |
| D20 | NCT-PIP-LL-0401 | Line 32"-CO2-2001-B9C design pressure 140 barg instead of 150 barg. | ✓ rule |
| D21 | NCT-PIP-LL-0401 | Line 16"-CO2-1002-B9C corrosion allowance 1.5 mm instead of 3.0 mm. | ✓ rule |
| D22 | NCT-PIP-LL-0401 | Vent line 2"-VNT-1005-L9C minimum design temperature -20 degC instead of -46 degC. | ✓ rule |
| D23 | NCT-INS-IL-0501 | Tag 110-PT-1011 appears twice. | ✓ rule |
| D24 | NCT-INS-IL-0501 | Instrument references P&ID NCT-PRC-PID-0399, which does not exist. | ✓ rule |
| D25 | NCT-INS-IL-0501 | Index range for 110-PT-1013 is 0-100 barg. | ✓ rule |
| D26 | NCT-PIP-CA-0601 | Calculation uses design pressure 135 barg. | ✓ rule |
| D27 | NCT-PIP-CA-0601 | Corrosion allowance 1.0 mm. | ✓ rule |
| D28 | NCT-PIP-CA-0601 | Line pipe grade L485ME is not an allowed grade. | ✓ rule |
| D29 | NCT-PIP-CA-0601 | Design factor 0.77 exceeds 0.72. | ✓ rule |
| D30 | NCT-MEC-PR-0701 | Houdtijd 8 uur (24 h required). | ✓ rule |
| D31 | NCT-MEC-PR-0701 | No drying section / dew point requirement. | ✓ rule |
| D32 | NCT-MEC-PR-0701 | Testdruk 210 barg (225 barg required). | ✓ rule |
| D33 | NCT-MEC-PR-0701 | Recorder calibration up to 12 months old allowed (6 months required). | ✓ rule |
| D35 | NCT-CIV-DW-0801 | Vent stack 45 m from the site boundary (60 m required). | ✓ rule |
| D36 | NCT-CIV-DW-0801 | Control room 22 m from the compressor building (30 m required). | ✓ rule |
| D37 | NCT-QAC-ITP-0901 | Girth weld NDT extent 10% instead of 100%. | ✓ rule |
| D38 | NCT-QAC-ITP-0901 | References procedure NCT-QAC-PR-0999, which is not in the document register. | ✓ rule |
| D39 | NCT-QAC-ITP-0901 | Pressure test is a hold point for the contractor only; the owner only reviews records (owner hold point required). | ✓ agent |
Counted as false positives for precision. Some may be genuine issues the corpus author did not plant; they are shown so you can judge.